<<Procedure of the "enforced performing of image quality control"/"control status check">>
Set the value for the number of times of sensor abnormality (08-2873) to "0".
Set the value for the Image quality closed-loop control (08-2844-0), (08-2844-1) to "0"
(valid).
Perform the "enforced performing of image quality control" (05-2120).
Check the control status of the image quality control (05-2133) and number of times of
sensor abnormality (08-2873).
Are both values for 05-2133 and 08-2873 "0"?
Perform the test print (04-114: Secondary scanning direction 33 gradation steps). Is the
image printed properly?
YES
NO
See " Troubleshooting for the Image" and clear the problem.
Is the value for 05-2133 "1"?
Attempt the procedure again from the beginning.
Is the value for 05-2133 "2"?
Pattern abnormality. Go back to "(1) Pattern abnormality " and clear the problem.
Is the value for 05-2133 "4"?
Sensor abnormality. Go back to "(2) Sensor abnormality" and clear the problem.
* When the value for 05-2160 (Drum surface potential sensor control status) is other than
"0", there is a problem on the drum surface potential control. Clear the problem with the
troubleshooting for surface potential control related.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
END
8 - 213
e-STUDIO556/656/756/856(Ver03)