Item
Subitem
Code
2052
2053
2054
2055
2057
2058
2059
2060
Sub-
Default
Acceptable
Details
code
value
value
Pre-running time for
5
0~15
first printing (OHP
film)
Pre-running time for
0
0~15
first printing(Plain
paper/Low
temperature
environment)
Pre-running time for
0
0~15
first printing(Thick
paper 1)
Pre-running time for
0
0~15
first printing(Thick
paper 2)
Fuser unit pre-running
Refer to
0~16
period end
contents
temperature(Pressure
roller)(Normal
temperature / Option
not installed)
Low-speed pre-
Refer to
0~16
running starting
contents
temperature during
ready status(Pressure
roller)(Option not
installed)
Low-speed pre-
Refer to
0~9
running stopping
contents
temperature during
ready status(Pressure
roller)(Option not
installed)
Threshold of low
7
0~11
temperature
environment control
2
RAM
Contents
M
0: Invalid 1: 0 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12
sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec.
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12
sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec.
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12
sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec.
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5 sec.
6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec. 11: 12
sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20 sec.
M
0: 100°C 1: 110°C 2: 120°C 3: 125°C 4: 130°C 5: 135°C
6: 140°C 7: 145°C 8: 150°C 9: 155°C 10: 160°C 11:165°
C 12: 170°C 13:175°C 14: 180°C 15:185°C
16: 190°C
<Default value>
e-STUDIO556 UC, EUR: 4
e-STUDIO656/756/856 JPC: 2 UC, EUR: 4
M
0: 50°C 1: 55°C 2: 60°C 3: 65°C 4: 70°C 5: 75°C 6: 80°
C 7: 85°C 8: 90°C 9: 95°C 10: 100°C 11:105°C 12: 110°
C 13:115°C 14: 120°C 15:125°C 16: 130°C
<Default value>
e-STUDIO556 UC, EUR: 16
e-STUDIO656 JPC: 6 UC, EUR: 16
e-STUDIO756/856 JPC: 16 UC, EUR: 16
M
0: 5°C 1: 10°C 2: 15°C 3: 20°C 4: 25°C 5: 30°C 6: 35°C
7: 40°C 8: 45°C 9: 50°C
<Default value>
e-STUDIO556 UC, EUR: 2
e-STUDIO656 JPC: 5 UC, EUR: 2
e-STUDIO756/856 JPC: 2 UC, EUR: 2
M
The boundary temperature of the low and normal
temperature control can be set.
0: 0°C 1: 5°C 2: 9°C 3: 10°C 4: 12°C 5: 14°C 6: 15°C 7: