[ 3 ] Connection
(1)
Connection for main charger measurement
( + ) : Rail for the main charger
(-) : Ground to the machine frame
(2)
Connection for developer bias measurement
© 2012 TOSHIBA TEC CORPORATION All rights reserved
Fig. 6-25
( + ) : Shaft of the upper developer sleeve
(-) : Ground to the machine frame
Fig. 6-26
6 - 43