Setting Of Fuser/Pressure Roller Temperature - Toshiba e-STUDIO556 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:
Table of Contents

Advertisement

6.13.2

Setting of fuser/pressure roller temperature

The fuser has been set (heat roller surface temperature: 200°C) taking the fusing performance,
wrinkling, curling and toner transfer deficiency at the leading/trailing edges of the duplex print into
consideration when our company recommended paper is used. This is to allow the characteristics of
the paper to be demonstrated in a well-balanced manner. However, various types of paper are used in
the field, and factors such as the paper thickness and smoothness greatly effect the fusing
performance, in particular. If the fusing performance deteriorates while using a specific type of paper,
deal with that by changing the fuser roller temperature at the setting mode "08".
Change the fuser roller temperature (in ready status, during printing).
To improve fusing efficiency, a change is made in the range of the setting value between "12" and "14"
(200°C to 210°C).
<Setting mode(08)>
Code
08-2009
Fuser roller temperature in ready status
08-2010
Fuser roller temperature during printing with plain paper
08-2049
Fuser roller temperature during printing with thick paper 1
08-2050
Fuser roller temperature during printing with thick paper 2
08-2028
Fuser roller temperature during printing with thick paper 3
08-2051
Fuser roller temperature during printing with OHP
Notes:
1. When a large value is set (to increase the temperature), the level of wrinkling, curling and
toner transfer deficiency at the leading/trailing edges of the duplex print tends to be
worsened.
2. Do not set the fuser roller temperature in the ready status (08-2009) higher than the one
during printing (08-2010, 08-2049, 08-2050, 08-2028).
3. When printing with OHP, remember that the OHP films tend to stick together if the setting
value for the fuser roller temperature (08-2051) is higher than the default value.
Change the starting temperature of the pressure roller low speed pre-running during ready in the setting
mode (08-2131, 08-2136). To improve the fusing quality, change the setting value to "12" (110°C).
Note:
The frequency of pre-running is increased when the starting temperature of the pressure roller
pre-runningduring ready is increased.
e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
Contents
© 2012 TOSHIBA TEC CORPORATION All rights reserved
6 - 64

Advertisement

Table of Contents
loading

Table of Contents