Toshiba e-STUDIO556 Service Manual page 905

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:
Table of Contents

Advertisement

Sub
05/08
Mode
Element
element
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Transfer
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Transfer
Temperature/humidity
t mode
sensor
05
Adjustmen
Process
Image
t mode
quality
control
05
Adjustmen
Process
Image
t mode
quality
control
Item
Subitem
Code
2162
2165
2166
2171
2188
2192
2194
2196
2198
Sub-
Default
Acceptable
Details
code
value
value
Drum surface
0
0-999
potential sensor
output (Latest
value)(Center voltage)
Drum surface
0
0-999
potential sensor
output (Latest
value)(Low voltage)
Drum surface
0
0-999
potential sensor
output (Latest
value)(High voltage)
Drum surface
0
0-999
potential sensor/
Residual voltage
sensor output(Latest
value)
Image quality open-
-
loop control
enforcement
Humidity display
60
0-100
Temperature display
22
0-50
Latest value of drum
22
0-100
temperature
Relative humidity
55
0-99
display at image
quality closed-loop
control
2
RAM
Contents
M
The drum surface potential of the main charger center
bias measured by the sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
M
The value of the main charger grid bias measured with
the drum surface potential sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
M
The value of the main charger grid bias measured with
the drum surface potential sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
M
The measured value of the residual voltage after
discharging is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
M
When a service call has occurred or a warning
message (IQC/SPC) has appeared, "Image quality
control enforcement (05-2120)" should be performed
after the equipment is repaired or the cause of the error
is evaluated. In case the service call occurred or the
warning message (IQC/SPC) appeared again after the
performance of the code 05-2120, a test chart can be
printed out by temporarily using this code (05-2188) if
an image check is urgently needed.
M
The humidity of the inside of the equipment is
displayed.[Unit: RH%]
M
The temperature of the inside of the equipment is
displayed.[Unit: °C]
M
A drum surface temperature detected at the drum
surface potential sensor control is displayed.
M
A relative humidity detected at the image quality closed-
loop control is displayed.
Proce
Servic
dure
e UI
2
2
2
2
6
2
Yes
2
Yes
2
2