When this item is selected, all data in the HDD are deleted and the HDD is reverted to its initial status at
the factory shipment.
This operation requires only a few seconds; however, you must reinstall the HDD data in the 49 mode
to make the HDD reusable.
When "1" is selected, the menu below appears.
To start, press the [START] button.
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
=>
1. Revert factory initial status HDD
2. Remove key
When the operation is finished, the result appears on the menu.
HDD Assist Mode
Current HDD type: ADI HDD
Select number (1-2) and press START key
1. Revert factory initial status HDD
=>
2. Remove key
Data in the HDD has been complately erased.
Press SoftPower Key to Switch Off
Note:
If the equipment is started in the normal mode with this condition, an HDD mounting error occurs.
[B] 2. Remove Key
Select this to reuse the HDD as well as the equipment.
When this item is selected, all data in the HDD except program data are deleted.
This operation requires approx. 20 minutes since the partition must be rebuilt.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
System Firmware Version
Update Mode
Confirmation Screen
Are you sure ???
Press START to continue
Press STOP to cancel