Operation Method - Hitachi VSP F1500 User And Reference Manual

Command control interface guide
Hide thumbs Also See for VSP F1500:
Table of Contents

Advertisement

Operation method

To execute a command on a device group, specify the name of the device
group (max: 32 characters) and the device name in the device group (max:
32 characters).
The following shows an example of mapping the LDEVs in a device group to
LUNs. When you specify both the device group name and the device name,
the operation is executed for the LDEV that matches the specified device
name in the specified device group. If you do not specify the device name,
the operation is executed for all LDEVs in the device group.
Information of the device group
C:\HORCM\etc>raidcom get device_grp -device_grp_name grp1
LDEV_GROUP
grp1
grp1
grp1
grp1
Result
The following shows the result of executing the raidcom add lun command
and specifying device group name: grp1 and device name: data0.
C:\HORCM\etc>raidcom add lun -port CL8-A -grp_opt ldev -device_grp_name
grp1 data0
GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17000(0x4268)[1], PORT =
CL8-A, LUN = none:
raidcom: LUN 0(0x0) will be used for adding.
done
GROUP = grp1, DEVICE = data0, UnitID = 0, LDEV = 17001(0x4269)[1], PORT =
CL8-A, LUN = none:
raidcom: LUN 1(0x1) will be used for adding.
done
C:\HORCM\etc>raidcom get lun -port CL8-A-0
PORT
CL8-A
CL8-A
The following shows the result of executing the raidcom add lun command
and specifying device group name: grp1 (omitting device name).
C:\HORCM\etc>>raidcom add lun -port CL8-A -grp_opt ldev -device_grp_name grp1
GROUP = grp1 , DEVICE = data0 , UnitID = 0 , LDEV = 17000(0x4268)[1] , PORT
= CL8-A
raidcom: LUN 0(0x0) will be used for adding.
done
GROUP = grp1 , DEVICE = data0 , UnitID = 0 , LDEV = 17001(0x4269)[1] , PORT
= CL8-A
raidcom: LUN 1(0x1) will be used for adding.
done
5-14
LDEV_NAME
data0
data0
data1
data1
GID
HMD
LUN
0
LINUX/IRIX
0
LINUX/IRIX
, LUN = none :
, LUN = none :
Provisioning operations with CCI
Command Control Interface User and Reference Guide
LDEV#
17000
17001
17002
17003
NUM
LDEV
CM
0
1
17000
-
1
1
17001
-
Serial#
64577
64577
64577
64577
Serial#
HMO_BITs
64577
64577

Hide quick links: