The commands as the target of the check are shown below.
raidcom modify port -port <port#> {[-port_speed <value>] [-loop_id
<value>][-topology <topology>] [-security_switch < y|n >] | -
port_attribute <port attribute>}
raidcom add external_grp -path_grp <path group#> -external_grp_id
<gnosgno> -port <port#> -external_wwn <wwn strings> -lun_id
<lun#> [-emulation <emulation type>] [-clpr <clpr#>]
raidcom add path -path_grp <path group#> -port <port#> -
external_wwn <wwn strings>
raidcom delete path -path_grp <path group#> -port <port#> -
external_wwn <wwn strings>
raidcom check_ext_storage path -path_grp <path group#> -port
<port#> -external_wwn <wwn strings>
raidcom disconnect path -path_grp <path group#> -port <port#> -
external_wwn <wwn strings>
raidcom add rcu {-rcu <serial#> <mcu#> <rcu#> <id> -ssid <ssid>| -
cu_free <serial#> <id> <pid>} -mcu_port <port#> -rcu_port <port#>
For example, if a path is attempted to be added to a port that does not exist,
an error is detected. An example of the script where the error is detected and
the execution result of the actual Context check are shown below.
Example of script (the text in bold indicates the part of incorrect
configuration definition.)
raidcom add path -path_grp 1 -port CL1-C -external_wwn 50060e80,06fc4180
raidcom add path -path_grp 1 -port CL1-D -external_wwn 50060e80,06fc4190
raidcom add path -path_grp 1 -port CL1-E -external_wwn 50060e80,06fc41a0
Execution result (the text in bold indicates the contents of the error
accompanying the invalid configuration definition in the script.)
C:\HORCM\etc>raidcom get port -store portcnf_27.dat
PORT TYPE ATTR SPD LPID FAB CONN SSW SL Serial# WWN
CL1-A FIBRE TAR AUT EF N FCAL N 0 64539 06fc1b000000fc1b
CL1-B FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b01
CL2-A FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b10
CL2-B FIBRE TAR AUT EF N FCAL N 0 64539 50060e8006fc1b11
CL3-A FIBRE TAR AUT E8 N FCAL N 0 64539 50060e8006fc1b20
CL3-B FIBRE TAR AUT E0 N FCAL N 0 64539 50060e8006fc1b21
CL4-A FIBRE TAR AUT D6 N FCAL N 0 64539 50060e8006fc1b30
CL4-B FIBRE TAR AUT D2 N FCAL N 0 64539 50060e8006fc1b31
CL5-A FIBRE TAR AUT E4 N FCAL N 0 64539 50060e8006fc1b40
CL5-B FIBRE TAR AUT DC N FCAL N 0 64539 50060e8006fc1b41
CL6-A FIBRE TAR AUT D5 N FCAL N 0 64539 50060e8006fc1b50
CL6-B FIBRE TAR AUT D1 N FCAL N 0 64539 50060e8006fc1b51
CL7-A FIBRE ELUN AUT E2 N FCAL N 0 64539 50060e8006fc1b60