Hitachi VSP F1500 User And Reference Manual page 371

Command control interface guide
Hide thumbs Also See for VSP F1500:
Table of Contents

Advertisement

Executing/
Error message
Get Command
Async
Status
Get Command
Async
Status
Get Command
Async
Status
Get Command
Async
Status
Get Command
Async
Status
Get Command
Async
Status
CMDRJE
Executing/
Async
Get Command
Status
CMDRJE
Executing
CMDRJE
Executing
CMDRJE
Executing
Get Command
Async
Status
Get Command
Async
Status
CMDRJE
Executing
Get Command
Async
Status
Get Command
Async
Status
CMDRJE
Executing
Get Command
Async
Status
Get Command
Async
Status
raidcom add journal
Error code
Async
SSB1
SSB2
2E10
0053
2E10
0056
2E10
0057
2E10
5000
2E11
800B
2E11
800E
2E11
810A
2E11
9400
2E20
0000
2E20
8300
2E21
5000
2E21
8104
2E21
8105
2E21
9000
2E23
0005
2E23
0008
2E23
003E
2E23
5000
Troubleshooting
Command Control Interface User and Reference Guide
Description
The specified volume is used in maintenance
operation.
The specified volume cannot be used as the journal
volume because the virtual LDEV ID is deleted.
The specified volume cannot be used as the journal
volume because it is the virtual volume.
The specified operation failed because the journal
or mirror is not in the operable status.
The operation cannot be performed because it is in
the state of start-up.
The operation cannot be performed because the
internal processing is in progress. Wait for a while,
then retry the operation.
Abnormal cache status.
The command cannot be accepted. After a while,
execute the same command.
The specified LDEV is not defined.
The specified MP Blade is not installed.
The operation failed because the specified journal
is not installed.
The journal volume cannot be added, or the
journal cannot be added to the extended
consistency group due to insufficient capacity of
the shared memory.
The shared memory for Universal Replicator is not
installed.
A journal volume cannot be registered, or a journal
cannot be added to the extended consistency
group because the program product of Universal
Replicator or Hitachi Universal Replicator for
Mainframe is not installed.
A new journal volume cannot be registered, or the
number of selected volumes is too many.
The number of specified LDEVs is invalid.
The operation failed because the multiple LDKC
numbers cannot be mixed in the journal.
The operation failed because the number of
journals in the journal or the extended consistency
group exceeds the maximum.
9-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents