Discovering A Remote Volume - Hitachi VSP F1500 User And Reference Manual

Command control interface guide
Hide thumbs Also See for VSP F1500:
Table of Contents

Advertisement

Figure 6-15 Volume discovery

Discovering a remote volume

The volume information discovered on the production servers is exported by
specifying the inqraid command with the -CLI option and -export option.
The volume information includes "Keyword, Serial#, Ldev#, Device file
name..". The raidscan -find inst command on CCI server imports the
volume information, and registers it into the HORCM daemon.
The inqraid command is needed only for discovering LUNs on the production
server.
Example of exporting by inqraid command (Solaris):
# ls /dev/rdsk/c1t* | inqraid -CLI -export
INQRAID:@CL4-G@64015@0@124@OPEN-V-CM@/dev/rdsk/c1t0d0s2
INQRAID:@CL4-G@64015@1@124@OPEN-V-CM@/dev/rdsk/c1t0d1s2
INQRAID:@CL4-G@64015@2@95@OPEN-V@/dev/rdsk/c1t0d2s2
INQRAID:@CL4-G@64015@3@95@OPEN-V@/dev/rdsk/c1t0d3s2
INQRAID:@CL4-G@64015@4@95@OPEN-V@/dev/rdsk/c1t0d4s2
INQRAID:@CL4-G@64015@5@95@OPEN-V@/dev/rdsk/c1t0d5s2
INQRAID:@CL4-G@64015@7@95@OPEN-V@/dev/rdsk/c1t0d7s2
6-59