Table 9-3 Generic error codes (horctakeover and pair commands)
Category
Syntax for Argument
(Unrecoverable)
Configuration
(Unrecoverable)
Command I/O to RAID
(Recoverable)
Communication for
HORCM
(Recoverable)
Recoverable
Error code
EX_REQARG
EX_INVARG
EX_INVNAM
EX_UNWOPT
EX_UNWCOD
EX_UNWCMD
EX_ERANGE
EX_ENAMLG
EX_INVRCD
EX_ENOGRP
EX_ENOENT
EX_ENODEV
EX_ENLDEV
EX_ENOUNT
EX_INVMUN
EX_ENQSER
EX_EXTCTG
EX_ENQCTG
EX_ENPERM
EX_ERPERM
EX_ESPERM
EX_CMDRJE
EX_CMDIOE
EX_OPTINV
EX_INVMOD
EX_INVCMD
EX_ATTHOR
EX_ATTDBG
EX_COMERR
EX_ENORMT
Troubleshooting
Command Control Interface User and Reference Guide
Error message
Required Arg list
Invalid argument
Invalid name of option
Unknown option
Unknown function code
Unknown command
Result too large
File name too long
Invalid return code
No such group
No such device or group
No such device
No such LDEV within the RAID
No such RAID unit
Invalid mu# with HORC or HOMRCF
Unmatched Serial# vs RAID unitID
Extended CTgroup across RAIDs
Unmatched CTGID within the group
Permission denied with the LDEV
Permission denied with the RAID
Permission denied with the SLPR
An order to the control/command was rejected 221
Control command I/O error, or rejected
A specified option is invalid
Invalid RAID command mode
Invalid RAID command
Cannot be attached to HORC manager
Cannot be attached to a Debug layer
Cannot be communicate with HORC manager
No remote host alive for remote commands, or
Remote CCI might be blocked (sleeping) on an
existing I/O.
Retur
n
Value
254
253
249
252
238
230
244
243
226
239
247
246
227
219
220
218
216
214
213
211
207
237
248
241
240
251
250
255
242
9-19