Error
Error
code
message
EX_ATTD
Can't be
Failed to communicate with
BG
attached
HORCM, or cannot make a
to a
log directory file.
Debug
layer
EX_INVN
Invalid
The name specified in an
AM
name of
argument of an option is not
option
appropriate.
EX_OPTI
A
Detected contradiction in
NV
specified
information that RAID
option is
reported.
invalid
EX_ENOE
No such
The designated device or
NT
device or
group name does not exist in
group
the configuration definition
file.
EX_ENOD
No such
The designated device name
EV
device
does not exist in the
configuration definition file.
EX_ENOU
No such
The designated RAID unit ID
NT
RAID unit
does not exist in the
configuration definition file.
EX_ENQS
Unmatche
The group designated by
ER
d Serial#
ShadowImage paircreate
vs RAID
does not have the same
unitID
RAID unit, or the unitID is
not identical to the unit ID in
the same RAID serial#
(Seq#).
EX_ENOM
Not
Insufficient memory exists.
EM
enough
core
EW_ENES
Cannot
The script file specified by
CR
execute
the -zt option cannot be
script file
performed.
EX_ERAN
Result too
Your entry is one of the
GE
large
following statuses.
EX_ENAM
File name
Undefined error.
LG
too long
Condition
The value was entered
beyond the maximum.
The result value is
beyond the maximum.
The unit you set is
invalid.
Troubleshooting
Command Control Interface User and Reference Guide
Recommended action
Verify that HORCM is running by using
UNIX commands [ps - ef | grep horcm].
Please designate the correct name using
the -h option.
Contact Hitachi Data Systems customer
support.
Verify the device or group name and
add it to the configuration definition file
of the remote and local hosts.
Verify the device name and add it to the
configuration definition file of the
remote and local hosts.
Verify the RAID unit ID and add it to the
configuration definition file of the
remote and local hosts.
Confirm the serial# (Seq#) of the
storage system using the pairdisplay
command, or confirm that the serial#
(Seq#) and the unit ID of storage
system are the same among hosts using
the raidqry -r command.
Increase the virtual memory capacity of
the system, or close any unnecessary
programs and/or daemon processes.
Confirm the execution right, permission
the extension, the execution path of the
script file.
Refer to the error message, and
designate an appropriate value or
confirm whether you specified the unit
correctly.
Contact Hitachi Data Systems customer
support.
Returne
d Value
250
249
248
247
246
219
218
245
131
244
243