Operating Power Supply For Switch Module; Server Blade Operation Setting When Power Failure Recovery - Hitachi COMPUTE BLADE 500 SERIES Management Module Setup Manual

Hide thumbs Also See for COMPUTE BLADE 500 SERIES:
Table of Contents

Advertisement

"Restart BMC" is used for recovery when an error occurs. Do not use it in
usual operation.
Tip: "Power OFF" is an emulation of pressing the server blade power button
for a second. "Force power OFF" is also that of pressing the server blade
power button for four seconds.
Power on, Power off, Forced
power off, Hard reset, Issuing
NMI
Rebooting BMC
Note:
*x: One of Server blade 0 – 7
Turning on
Turning off / Forced turning off
Hard reset / Issuing NMI
Rebooting BMC

Operating power supply for switch module

You can turn on or off the switch module by the management module.
Tip: The switch module boot up automatically when turn on AC. You do not
need turn the switch module on.
Operating power supply for switch
module
Note:
*x: One of Switch module 0 – 3

Server blade operation setting when power failure recovery

You can perform the server blade operations as following by setting the
management module configuration when turning on the system unit.
Hitachi Compute Blade 500 Series Management Module Setup Guide
Table 2-50 Web console operation
Item
Resources tab > Modules > All Modules > Server
Blades > Server Blade x > Condition tab
Resources tab > Modules > All Modules > Server
Blades > Server Blade x > BMC tab
Table 2-51 CLI console command
Item
Table 2-52 Web console operation
Item
Functional detail
Operation
poweron blade
poweroff blade
reset blade
bmc-reset blade
Operation
Resources tab > Modules > All modules >
Switch Module > Switch Module x
Command
2-43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents