LU#: Defines the iSCSI/Fibre logical unit number (LU#) of the physical
volume on the specified target ID and port.
Note: In case of fibre channel, if the TID and LU# displayed on the
system are different than the TID on the fibre address conversion table,
then you must use the TID and LU# indicated by the raidscan command
in the CCI configuration file.
MU# for ShadowImage (HOMRCF): Defines the mirror unit number (0 - 2)
to use the redundant mirror for the identical LU on the ShadowImage. If
this number is omitted, it is assumed to be (MU#0). The cascaded
mirroring of the S-VOL is expressed as virtual volumes using the mirror
descriptors (MU#1-2) in the configuration definition file. The MU#0 of a
mirror descriptor is used for connection of the S-VOL. The mirror
descriptor (MU#0-2) can be used in ShadowImage and Copy-on-Write
Snapshot. MU#3-63 can be used in Copy-on-Write Snapshot only.
Note: When you enter the MU number for a ShadowImage/Copy-on-
Write Snapshot pair into the configuration definition file, enter only the
number, for example, "0" or "1".
Feature
ShadowImage
Copy-on-Write
Snapshot
MU# for TrueCopy/Universal Replicator/global-active device: Defines the
mirror unit number (0 - 3) if using redundant mirror for the identical LU
on TC/UR/GAD. If this number is omitted, it is assumed to be (MU#0).
You can specify only MU#0 for TrueCopy, and 4 MU numbers (MU#0 - 3)
for Universal Replicator and global-active device.
Note: When you enter the MU number for a TC/UR/GAD pair into the
configuration definition file, add an "h" before the number, for example,
"h0" or "h1".
Feature
TrueCopy
UR

HORCM_INST

The instance parameter (HORCM_INST) defines the network address (IP
address) of the remote server (active or standby). It is used to view or
change the status of the paired volume in the remote server (active or
standby). When the primary volume is shared by two or more servers, there
SMPL
MU#0-2
MU#3 - 63 MU#0-2 MU#3 - 63 MU#0 MU#1 - 63
Valid
Not valid
Valid
Valid
SMPL
MU#0
MU#1 - 3
Valid
Not valid
Valid
Valid
CCI software environment
Command Control Interface User and Reference Guide
P-VOL
Valid
Not valid
Valid
Valid
P-VOL
MU#0
MU#1 - 3
Valid
Not valid
Valid
Valid
S-VOL
Valid
Not valid
Valid
Not valid
S-VOL
MU#0
MU#1 - 3
Valid
Not valid
Valid
Valid
2-25