rootcause

To specify the root-cause alarm message, use the rootcause command in stateful or nonstateful correlation
rule configuration modes.
rootcause msg-category group-name msg-code
no rootcause
Syntax Description
msg-category
group-name
msg-code
Command Default
Root-cause alarm is not specified.
Command Modes
Stateful correlation rule configuration
Nonstateful correlation rule configuration
Command History
Release
Release 3.6.0
Usage Guidelines
This command is used to configure the root-cause message for a particular correlation rule. Messages are
identified by their message category, group, and code. The category, group, and code each can contain up to
32 characters. The root-cause message for a stateful correlation rule should be a bi-state alarm.
Use the
for a correlation rule.
Task ID
Task ID
logging
Examples
This example shows how to configure a root-cause alarm for a stateful correlation rule:
RP/0/0/CPU0:router(config)# logging correlator rule state_rule type stateful
RP/0/0/CPU0:router(config-corr-rule-st)# rootcause L2 SONET_LOCAL ALARM
OL-24735-01
show logging events info, on page 62
Cisco IOS XR System Monitoring Command Reference for the Cisco XR 12000 Series Router, Release 4.1
Message category of the root message.
Group name of the root message.
Message code of the root message.
Modification
This command was introduced.
command to display the root-cause and non-root-cause alarms