K Es100@ Digital Controller Protocol - Omron SYSMAC CS1W-SCB41-V1 Operation Manual

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

The ES100@ Digital Controller Protocol controls in remote mode and reads various settings from the Controller
connected to the Serial Communications Unit/Board via RS-232C or RS-422A/485 cable.
Note Negative values cannot be written. All values must be set as unsigned BCD.
Structure of the Protocol
The structure of the ES100@ Digital Controller Protocol is shown below.
Sequence
Transmission
No.
sequence name
250 (00FA)
Read event data
251 (00FB) Read time signals
252 (00FC) Read error detection
data
253 (00FD) Read heater burnout
data
254 (00FE) Read PV data
255 (00FF)
Read SP data
256 (0100)
Read MV
257 (0101)
Read control monitor
data
258 (0102)
Read adjustment
parameters
259 (0103)
Write adjustment
parameters
260 (0104)
Read PID control
parameters 1
261 (0105)
Read PID control
parameters 2
262 (0106)
Write PID control
parameters 1
263 (0107)
Write PID control
parameters 2
264 (0108)
Read local SP
265 (0109)
Write local SP
266 (010A)
Read program parame-
ters
267 (010B)
Write program parame-
ters
268 (010C) Remote setting mode
269 (010D) Local setting mode
270 (010E)
External setting mode
Appendix K
ES100@ Digital Controller Protocol
Reads events 1 to 10 in the variable area.
Reads time signals 1 to 10 in the variable
area.
Reads error groups 1 to 15 in the variable
area.
Reads the heater burnout alarm.
Reads PV data in the variable area.
Reads SP data in the variable area.
Reads the MV in the variable area.
Reads control monitor data (SP, PV, and MV)
in the variable area.
Reads adjustment parameters in the parame-
ter area.
Writes adjustment parameters in the parame-
ter area.
Reads PID parameters No. 1 to 4 from the
PID control parameters in the parameter
area.
Reads PID parameters No. 5 to 8 from the
PID control parameters in the parameter
area.
Writes PID parameters No. 1 to 4 from PID
control parameters in the parameter area.
Writes PID parameters No. 5 to 8 from PID
control parameters in the parameter area.
Reads the local SP in the program parameter
area.
Writes local SP in the program parameter
area.
Reads local SP, step time, PID No. wait code,
and events 1 to 10 set values in the program
parameter area.
Writes the local SP, step time, PID No., wait
code, and event 1 to 10 set values in the pro-
gram parameter area.
Switches the setting mode to remote setting.
Switches the setting mode to local setting.
Switches the setting mode to external setting.
Function
Ladder interface
Send word
Receive word
allocation
allocation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
No
559

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents