Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 675

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

3Z4L Laser Micrometer Protocol
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1. This sequence cannot be used to set the error lower limit (EL), error upper limit (EH), error exclusion
counter (CNT) of the error data exclusion function (centerless grinder function).
2. The following settings must be made together with this sequence; they cannot be set separately.
Lower limit, upper limit
Multistep selection limit
Reference value, analog output scale number
Data output conditions, scheduled print timer
3. The limit value, reference value, and offset value can be set to 3 digits for the integer portion and to
4 digits for the decimal portion.
646
Offset
Contents (data format)
+33
Analog output scale number
(1 digit BCD)
+34 to
Offset classification (ASCII 3
+35
characters)
+36 to
Offset value
+38
+39
Data output conditions
(1 digit BCD)
+40
Scheduled output timer
(3 digits BCD)
+41
Sample measurement pulse
(3 digits BCD)
+42 to
Sample measurement clas-
+43
sification
(ASCII 3 characters)
+44 to
Unused
+45
+46
Yes/No for segment setting
(1 digit BCD)
+47
Yes/No for measurement
interval number setting
(1 digit BCD)
+48
Yes/No for upper/lower limit
value setting
(1 digit BCD)
+49
Yes/No for multistep selec-
tion limit value
(1 digit BCD)
+50
Yes/No for reference setting
(1 digit BCD)
+51
Yes/No for offset value set-
ting (1 digit BCD)
+52
Yes/No for data output condi-
tion setting
(1 digit BCD)
+53
Yes/No for sample measure-
ment pulse setting
(1 digit BCD)
Data
1 to 3
4F4620 ("OF"), 4F4D20 ("OM")
Same as lower limit values
0 to 6
000 to 999
000 to 999
415647 ("AVG"), 4D4158 ("MAX")
4D494E ("MIN"), 524E47 ("RNG")
Undefined
Set:
1 (SG)
Don't set: 0
Set:
1 (M)
Don't set: 0
Set:
1 (LL,LH)
Don't set: 0
Set:
1 (L1,L2,L3,L4,L5,L6)
Don't set: 0
Set:
1 (REF,SCL)
Don't set: 0
Set:
1 (OF or OM)
Don't set: 0
Set:
1 (PR,PRT)
Don't set: 0
Set:
1 (SMP, MAX or MIN or RNG or AVG)
Don't set: 0