Troubleshooting
Transmission Failure (TXD(236), TXDU(256))
Error conditions
Serial communi-
Indicator
cations mode
display
Serial communi-
---
cations mode is
no-protocol mode
Board
---
Unit: Protocol
---
macro mode,
NT Link, loop-
back test
Unit: Host
Link
Words allocated in CIO
Status and
other condi-
tions
---
CIO Area word n+5/n+15 bits
12 to 15 (serial communica-
tions mode) is set to a value
other than 3 hex.
---
Bit A42404 (Inner Board ser-
vice failure) in the Auxiliary
Area is ON when the
TXD(236) instruction is exe-
cuted.
---
During execu-
tion of the
TXDU(256)
instruction
Cause
Area
The serial com-
munications
mode is not set
correctly.
The serial com-
munications
mode is not set
correctly.
Or
A no-protocol
instruction was
sent using no-
protocol mode to
a Board that
does not support
no-protocol com-
munications (pre-
Ver.1.2).
FINS end
The serial com-
code such as
munications
0401 hex
mode is not set
(undefined
correctly.
command) is
Or
returned.
A no-protocol
FINS end
instruction was
code such as
sent using no-
0205 hex
protocol mode to
(response
a Board that
timeout) is
does not support
returned.
no-protocol com-
munications (pre-
Ver.1.2).
Section 11-3
Remedy
---
Set bits 08 to 11 of
DM Area word m/
m+10 (serial com-
munications mode)
to 3 hex (no-proto-
col mode).
Or
Install a Board with
Unit Ver. 1.2 or later
that supports no-
protocol communi-
cations, and after
replacing, set the
serial communica-
tions mode to no-
protocol mode.
Set bits 08 to 11 of
DM Area word m/
m+10 (serial com-
munications mode)
to 3 hex (no-proto-
col mode).
Or
Install a Board with
Unit Ver. 1.2 or later
that supports no-
protocol communi-
cations, and after
replacing, set the
serial communica-
tions mode to no-
protocol mode.