E5ZE Temperature Controller Read Protocol
Read Proportional Band, Integral Time, and Derivative Time
(Sequence No. 104 (Hex 0068))
Reads the proportional bands (constant P), integral times (constant I), and derivative times (Constant D) and
stores the results in the specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Offset
Contents (data format)
+0
Number of receive data words
(4 digits Hex)
+1
Channel 0
Set point (rightmost 4 digits)
(4 digits BCD)
+2
Channel 0
Set point (leftmost 1 digit) (1 digit BCD)
+3
Channel 0
Process value (rightmost 4 digits)
(4 digits BCD)
+4
Channel 0
Process value (leftmost 1 digit)
(1 digit BCD)
+5
Channel 0
Output value (4 digits BCD)
+36
Channel 7
Set point (rightmost 4 digits)
(4 digits BCD)
+37
Channel 7
Set point (leftmost 1 digit) (1 digit BCD)
+38
Channel 7
Process value (rightmost 4 digits)
(4 digits BCD)
+39
Channel 7
Process value (leftmost 1 digit)
(1 digit BCD)
+40
Channel 0
Output value (4 digits BCD)
+0
Number of send data words
+1
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Unit No. (2 digits Hex)
+0
Number of receive data words
+1
Constant P
+2
Constant I
+3
Constant D
~
+22
Constant P
Constant I
+23
+24
Constant D
0029 (0041 decimal)
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
0000 to 1000
•
•
•
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
Varies according to the temperature sensor
type. Refer to the manual for the E5ZE.
0000 to 1000
Unit No.
0002 (fixed)
00 to 0F
Channel 0
~
Channel 7
Appendix H
Data
Data
509