E5@K Digital Controller Write Protocol
The E5@K Digital Controller Write Protocol writes and controls various settings in remote mode for the Control-
ler connected to the Serial Communications Unit/Board via RS-232C or RS-485 cable.
Note Negative values cannot be written. All values must be set as unsigned BCD.
Structure of the Protocol
The following table shows the structure of the E5@K Digital Controller Write Protocol.
Sequence
Communications
No.
sequence name
050 (0032)
Write set point
051 (0033)
Write alarm value
052 (0034)
Write proportional band,
integral time, and derivative
time
053 (0035)
Write cooling coefficient
054 (0036)
Write dead band
055 (0037)
Write manual reset value
056 (0038)
Write hysteresis
057 (0039)
Write control period
058 (003A)
Write SP ramp time units
and set value
059 (003B)
Write LBA detection time
060 (003C) Write MV at stop time and
PV error
061 (003D) Write MV limits
062 (003E)
Write input digital filter
063 (003F)
Write alarm hysteresis
064 (0040)
Write input shift values
065 (0041)
Write level 0 parameters
066 (0042)
Write level 1 parameters 1
067 (0043)
Write level 1 parameters 2
068 (0044)
Write level 2 parameters 1
069 (0045)
Write level 2 parameters 2
070 (0046)
General-purpose write
071 (0047)
Switch to level 0
(software reset)
072 (0048)
Run/stop
073 (0049)
Remote/local
074 (004A)
Execute/cancel AT
075 (004B)
Switch to level 1
076 (004C) Software reset
Note 1. The hexadecimal equivalents of sequences numbers are given in parentheses.
2. Ladder Interface Settings
YES: User settings are required for the 3rd or 4th operands of PMCR.
Appendix G
Function
Writes the set point.
Writes alarm value 1, 2.
Writes the proportional band, integral
time, and derivative time.
Writes the cooling coefficient.
Writes the dead band.
Writes the manual reset value.
Writes the hysteresis (heating, cooling)
Writes the control period (heating,
cooling)
Writes the SP ramp time unit and SP
ramp set value.
Writes the LBA detection time.
Writes the MV at stop and the MV at PLC
error.
Writes the MV limits.
Writes the input digital filter.
Writes alarm 1, 2 hysteresis.
Writes the input shift values.
Writes parameters in level 0.
Writes parameters in level 1.
Writes parameters in level 1.
Writes parameters in level 2.
Writes parameters in level 2.
Writes the value of the specified
parameter.
Switches the setting level to level 0.
Initiates Run or Stop.
Switches the mode to remote or local.
Executes or cancels AT.
Switches the setting level to level 1.
Resets the E5@K.
Ladder interface
Send word
Receive word
allocation
allocation
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
485

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents