V500/V520 Bar Code Reader Protocol
BCR Function Write (V500) (Sequence No. 345 (Hex 0162))
This sequence sets the operation mode and read functions in the Bar Code Reader.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Note Selecting the values marked with asterisks is required for this protocol.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
+0
Number of send data words
+1
Operation mode
+2
Types of bar code
+3
Number of digits
(Undefined)
+4
Modulus check
Number of
+5
(Undefined)
matches
Horizontal control
+6
Buzzer
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Operation mode
(ASCII 1 character)
In-zone control
(ASCII 1 character)
+2
Bar code type
(ASCII 1 character)
+3
Number of digits
(2 digits BCD)
+4
Modulus check
(ASCII 1 character)
+5
Number of matches
(1 digit BCD)
Multistep labels
(1 digit BCD)
+6
Buzzer
(ASCII 1 character)
Horizontal control mode
(ASCII 1 character)
In-zone control
(Undefined)
(Undefined)
Multistep
labels
0007 (fixed)
41 ('A'):
ONLINE
*42 ('B'): ONLINE CONTROL
*41 ('A'): ON
42 ('B'):
OFF
41 ('A'):
JAN
42 ('B'):
NW7 NORMAL
43 ('C'): NW7 SMALL
44 ('D'): NW7 HEX
45 ('E'):
CODE39 NORMAL
46 ('F'):
CODE39 ST/SP OUTPUT
47 ('G'): 2 of 5 (ITF)
48 ('H'): CODE128
49 ('I'):
CODE93
4A ('J'):
2 of 5 (3BAR)
4B ('K'): 2 of 5 (5BAR)
00 to 32
00: Any number of digits allowed.
41 ('A'):
No-check
42 ('B'):
Modulus 10 (all bar codes)
43 ('C'): Modulus 11 (except JAN)
44 ('D'): Modulus 16 (NW7 only)
45 ('E'):
Modulus 43 (CODE39 only)
46 ('F'):
Modulus 47 (CODE93 only)
47 ('G'): Modulus 103 (CODE128 only)
1 to 5
1 to 4
41 ('A'):
ON for normal read
42 ('B'):
ON for no-read
43 ('C'): OFF
41 ('A'):
Normal (continuous rotating)
42 ('B'):
In-zone startup