Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 640

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

K3T @ Intelligent Signal Processor Protocol
Read Set Value L (Continuous Units) (Sequence No. 320 (Hex
0140))
This sequence reads set value L for continuous units. The word allocation is identical to that of sequence No.
318 (Read Set Value HH (Continuous Units)).
Read Set Value LL (Continuous Units) (Sequence No. 321 (Hex
0141))
This sequence reads set value LL for continuous units. The word allocation is identical to that of sequence No.
318 (Read Set Value HH (Continuous Units)).
Read Set Value with Bank (by Unit Number) (Sequence No. 322
(Hex 0142))
Reads the set value of a bank which is not in use (K3TR: HH to LL, K3TC:01 to 05) and stores the results in the
specified words.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
+0
Number of send data words
(Undefined)
+1
Number of units
(Undefined)
Relevant unit No.
+2
+3
(Undefined)
Operand
+4
~
+95
(Undefined)
Relevant unit No.
(Undefined)
+96
Operand
+97
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Number of units (4 digits Hex)
+2
Relevant unit No. (2 digits BCD)
+3
Bank No. (2 digits BCD)
+4
Operand (ASCII 2 characters)
+ 97
Operand (ASCII 2 characters)
Bank No.
~
Bank No.
0005 to 0062 (5 to 98 decimal)
0001 to 0020 (1 to 32 decimal)
00 to 99
01 to 04
4848 ("HH"),
4820 ("H"),
4C20 ("L"),
4C4C ("LL"),
Same as above
Appendix L
Data
4F31 ("O1")
4F32 ("O2")
4F33 ("O3")
4F34 ("O4")
4F35 ("O5")