Auxiliary Area and CIO Area Allocations
Name
Address
Executed
Board:
Step No.
CIO 1911 bits 08 to
(code)
11 (port 1)
CIO 1921 bits 08 to
11 (port 2)
Unit:
n + 11 bits 08 to 11
(port 1)
n + 21 bits 08 to 11
(port 2)
Executed
Board:
Reception
CIO 1910 bits 00 to
Case No.
03 (port 1)
(code)
CIO 1920 bits 00 to
03 (port 2)
Unit:
n + 10 bits 00 to 03
(port 1)
n + 20 bits 00 to 03
(port 2)
Executed
Board:
Reception
CIO 1912 bits 00 to
Case No.
15 (port 1)
Flags
CIO 1922 bits 00 to
15 (port 2)
Unit:
n + 12 bits 00 to 15
(port 1)
n + 22 bits 00 to 15
(port 2)
Executed
Board:
Step No.
CIO 1913 bits 00 to
Flags
15 (port 1)
CIO 1923 bits 00 to
15 (port 2)
Unit:
n + 13 bits 00 to 15
(port 1)
n + 23 bits 00 to 15
(port 2)
174
Meaning
Step numbers 0 to 15 (0 to F hex) are stored
for the steps for which execution has been
completed.
Reception matrix case numbers 0 to 15 (0 to
F hex) are stored for which reception has
been completed. The number is cleared
when the sequence execution starts, when
the STUP(237) instruction is executed, and
at restarts.
The Executed Reception Case No. is stored
only when the reception matrix is set using
the RECV or SEND&RECV command. If a
reception matrix is not set, the case number
will be set to 0 (cleared) when another com-
mand is executed.
Reception matrix case numbers 0 to 15 for
which reception has been completed corre-
spond to individual bits (00 to 15), and are
turned ON to indicate execution. The num-
bers are cleared when the sequence execu-
tion starts, when the STUP(237) instruction
is executed, at restarts, and when the execu-
tion of each step starts.
The reception matrix case number can be
checked from the ladder program when the
WAIT command is executed or when the
sequence is ended after the reception matrix
RECV command is executed.
The Executed Reception Case No. Flag in
the bit corresponding to the stored case
number will be turned ON only when the
reception matrix is set for the RECV or
SEND&RECV command. If a reception
matrix is not set, the case number will be set
to 0 (cleared) when another command is
executed.
Case numbers 0 to 15 for the steps for which
execution has been completed correspond to
individual bits (00 to 15), and are turned ON
in ascending order. Once a bit has been exe-
cuted, the bit corresponding to the executed
step is turned ON in ascending order to hold
the bit ON during the sequence (and after
completion).
Section 5-3
Timing
Initialize
ON
Startup
When step
When
(see note)
is exe-
sequence
cuted
starts
Startup
When
When
(see note)
matrix is
sequence
received
starts
Startup
When
When
(see note)
matrix is
sequence
received
starts
Startup
When step
When
(see note)
is exe-
sequence
cuted
starts
OFF

Hide quick links: