Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 681

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

Appendix N
3Z4L Laser Micrometer Protocol
Data Request (3000-series) (Sequence No. 415 (Hex 019F))
This sequence requests display data in the idle measurement status or the latch data generated by the mea-
surement command.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
The receive data word allocation is similar to that of sequence No. 410 (Single Run Measurement Start).
Statistic Processing Execution (3000-series) (Sequence No. 416
(Hex 01A0))
This sequence lights the statistic processing LED and implements the statistic processing.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Statistic Processing Non-execution (3000-series)
(Sequence No. 417 (Hex 01A1))
This sequence turns the statistic processing LED off and does not carry out the statistic processing.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
All Statistic Memory Clear (3000-series) (Sequence No. 418 (Hex
01A2))
This sequence clears statistic processing memories of all programs.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Statistic Processing Memory Clear (3000-series)
(Sequence No. 419 (Hex 01A3))
This sequence clears statistic processing memories of the program under display.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
652

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents