Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 688

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

3Z4L Laser Micrometer Protocol
Measurement Condition Set (4000-series) (Sequence No. 431
(Hex 01AF))
This sequence sets measurement conditions. Conditions to be set can be selected by setting Yes/No flags.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
+0
send data
+1
+2
+3
+4
+5
+6
+7
+8
+9
+10
+11
+12
+13
+14
+15
+16
+17
+18
+19
+20
+21
+22
+23
+24
Number of send data words
(Undefined)
(Undefined)
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
Decimal portion
(Undefined)
Integer portion
Sign
(Undefined)
(Undefined)
(Unused)
(Unused)
(Unused)
(Undefined)
(Undefined)
Data output timer (BCD 3 digits)
(Undefined)
0
0
0
0
0
0
Segment number (SG)
Measurement interval number (M)
Lower limit value (LL)
Upper limit value (LH)
Reference value (REF)
Analog output scale number (SCL)
Data output conditions (PR)
(PRT)
Number of seconds for latch timer (RLT)
Setting Yes/No flags
Appendix N
659

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents