Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 689

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

3Z4L Laser Micrometer Protocol
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Note 1. The following settings must be made together with this sequence; they cannot be set separately.
Lower limit, upper limit
Reference value, data output timer
Data output conditions, scheduled print timer
2. The limit value and reference value can be set to 3 digits for the integer portion and to 4 digits for the
decimal portion.
660
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Segment number
(1 digit BCD)
+2
Measurement interval num-
ber (1 digit BCD)
+3
Lower limit value (Decimal
portion)
(4 digits BCD)
+4
Lower limit value (integer
portion) (3 digits BCD)
+5
Lower limit value (Sign)
(ASCII 1 character)
+6 to +8 Upper limit value
+9 to
Reference value
+11
+12
Analog output scale number
(1 digit BCD)
+13 to
Unused
+15
+16
Data output conditions
(1 digit BCD)
+17
Data output timer value
(3 digits BCD)
+18
Number of seconds for latch
timer
(2 digits BCD)
+19
Yes/No for segment setting
(1 digit BCD)
+20
Yes/No for measurement
interval number setting
(1 digit BCD)
+21
Yes/No for upper/lower limit
value setting
(1 digit BCD)
+22
Yes/No for reference setting
(1 digit BCD)
+23
Yes/No for data output condi-
tion setting
(1 digit BCD)
+24
Yes/No for latch timer setting
(1 digit BCD)
Data
0019 (0025 decimal) (fixed)
1 to 5
1 to 7
0000 to 9999
000 to 999
If +: 20 (' ')
If –: 2D ('–')
Same as lower limit value
Same as lower limit value
0 to 3
0 to 6
000 to 999
00 to 99
Set:
1(SG)
Don't set: 0
Set:
1(M)
Don't set: 0
Set:
1(LL, LH)
Don't set: 0
Set:
1(REF, SCL)
Don't set: 0
Set:
1(PR, PRT)
Don't set: 0
Set:
1(RLT)
Don't set: 0
Appendix N
Example –123.4567
+3
4 5 6 7
+4
0 1 2 3
+5
2 D 0 0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents