Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 629

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

K3T @ Intelligent Signal Processor Protocol
Sequence
Communications
No.
sequence name
319 (013F)
Read set value H (contin-
uous units)
320 (0140)
Read set value L (contin-
uous units)
321 (0141)
Read set value LL (con-
tinuous units)
322 (0142)
Read set value with bank
(by unit number)
323 (0143)
Read set value HH with
bank (continuous units)
324 (0144)
Read set value H with
bank (continuous units)
325 (0145)
Read set value L with
bank (continuous units)
326 (0146)
Read set value LL with
bank (continuous units)
327 (0147)
Read set value O5 with
bank (continuous units)
328 (0148)
Read set value O4 with
bank (continuous units)
329 (0149)
Read set value O3 with
bank (continuous units)
330 (014A)
Read set value O2 with
bank (continuous units)
331 (014B)
Read set value O1 with
bank (continuous units)
332 (014C) Read holding data (by
unit number)
333 (014D) Read holding data PH
(continuous units)
334 (014E)
Read holding data BH
(continuous units)
335 (014F)
Read display value (PV)
(by unit number)
336 (0150)
Read display value (PV)
(continuous units)
337 (0151)
Read model (by unit
number)
338 (0152)
Read model (continuous
units)
339 (0153)
General-purpose com-
mand
Note 1. Special specifications are required to use communications + comparison output.
2. Special specifications are required to use communications + comparison output for the K3TR and
K3TC. The operands HH, H, L, and LL are for the K3TR, and the operands O5, O4, O3, O2, and O1
are for the K3TC.
3. Not available for the K3TC.
4. The hexadecimal equivalents of sequences numbers are given in parentheses.
600
Function
Reads the set value H.
Reads the set value L.
Reads the set value LL.
Reads set value of a bank which is
not in use (K3TR: HH to LL, K3TC:
O1 to O5).
Reads the set value HH of a bank
which is not in use.
Reads the set value H of a bank
which is not in use.
Reads the set value L of a bank
which is not in use.
Reads the set value LL of a bank
which is not in use.
Reads the set value O5 of a bank
which is not in use.
Reads the set value O4 of a bank
which is not in use.
Reads the set value O3 of a bank
which is not in use.
Reads the set value O2 of a bank
which is not in use.
Reads the set value O1 of a bank
which is not in use.
Reads the peak/bottom data (max-
imum, minimum).
Reads the peak data (maximum).
Reads the bottom data (minimum).
Reads the display value (PV).
Reads the display value (PV).
Reads the model data.
Reads the model data.
Send specified data or receives
specified data and writes it to the
receive data words.
Appendix L
Ladder interface
Send word
Receive word
allocation
allocation
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Notes
1
1
1
2
1
1
1
1
1
1
1
1
1
3
3
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents