Omron SYSMAC CS1W-SCB41-V1 Operation Manual page 733

Sysmac cs series; sysmac cj series. serial communications boards and serial communications units
Table of Contents

Advertisement

V600/V620 ID Controller Protocol
Read (Hex/8) (Sequence No. 507 (Hex 01FB))
This sequence is used when the maximum number of Heads to be read from the Carrier is 8. Up to 10 bytes of
data can be read for each Read/Write Head.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
704
+0
Number of send data words
+1
Number of Heads
+2
(Undefined)
+3
(Undefined)
Leading address No.
+4
(Undefined)
+5
(Undefined)
+6
(Undefined)
+7
Leading address No.
+8
(Undefined)
+9
~
(Undefined)
+30
+31
(Undefined)
+32
Leading address No.
+33
(Undefined)
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Number of Heads
(4 digits BCD)
+(4(N–1)+2)
Unit No. (2 digits BCD)
+(4(N–1)+3)
R/W Head CH No.
(1 digit BCD)
+(4(N–1)+4)
Leading address No.
(4 digits Hex)
+(4(N–1)+5)
Read bytes
(2 digits Hex)
N: Number of Heads
Unit No.
Head CH No.
CH 1
Read bytes
Unit No.
Head CH No.
CH 2
Read bytes
~
Unit No.
Head CH No.
CH 8
Read bytes
0006 to 0022 (6 to 34 decimal)
0001 to 0008
Arbitrary (However, there is a limit for the
maximum Unit No. depending on the model)
R/W Head CH 1 designation: 1
R/W Head CH 2 designation: 2
The CD1D must be set to 1.
0000 to FFFF
01 to 0A (1 to 10 bytes)
Appendix P
Data