CompoWay/F Master Protocol
General-purpose Broadcast with No Conversion and No Response
(Sequence No. 605 (Hex 025D))
This sequence broadcasts the specified data beginning with the subaddress and SID. No responses are
received and no conversions are performed on the send data.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None. (Specify a dummy value for the operand, such as #0000.)
Offset
Contents (data format)
+2
Receive data
on
+0
+2
+4
+6 etc.
+0
First word of
Number of send data words
send data
+1
+2
(Undefined)
+3
(Undefined)
+4
+5
Offset
Contents (data format)
+0
Number of send data words
(4 digits Hex)
+1
Always 0000 Hex
+2
MRC
(2 digits Hex)
+3
Always 00 Hex
+4
Number of send bytes (4 digits Hex)
+5
Send data
on
+0
+2
+4
+6 etc.
The data from just after the response code
until just before the ETX is stored here with-
+1
out conversion.
+3
+5
(Undefined)
Subaddress
SID
Number of send bytes
Send data
0006 to 00FA Hex (6 to 250 decimal)
---
Subaddress
Specify the subaddress of the device being
(2 digits Hex)
communicated with.
SID (1 digit Hex)
Set the service ID of the required service
(e.g., retries).
Number of data bytes from the MCR until
the byte just before the ETX.
0000 to 01EA Hex (0 to 490 decimal)
The data specified in hexadecimal here is
not converted and the number of bytes
+1
specified in S+4 is sent.
+3
+5