IMPORTANT
• Click [Apply] after saving or reading of Network drive. If you click it while Network drive is running, Network drive's file
could be given a damage.
IMPORTANT
• If images and data are logged to a network drive, the use of the multi-input function and other heavy measurement loads
on the Controller may slow down communications and cause logging errors. In this case, set the measurement takt time
so that there is some leeway.
• If many drives are set as network drives, it may require a greater amount of time to start the Controller.
• Do not pull out the LAN cable while the Controller is accessing the network drives.
• Start the Controller when the network drives are ready. Connections cannot be established if the network drives are not
ready when the Controller is started.
• If there is no access to a network drive for a certain amount of time, the connection will be automatically cut off
depending on the network drive setting at the connection target. Make sure that the setting at the connection target is not
set to automatic disconnection.
• Dates and Times of the Updates of the Files Created at Network Logging
If the time zone of the external device is different from the time zone setting of the Controller [GMT-08:00 Pacific Time
(US & Canada): Do not automatically adjust clock for Daylight Saving Time], the date and time actually written may be
different from the date and time of the file update. Adjust the time zone of the external device to match that of the
Controller.
• For Network drive communication with the FH series/FZ5-1100 series, you can specify IP address instead of Host name
on the Shared file setting. On the other hand, in the case of FZ5-L series/FZ5-600 series, Network drive communication
cannot be apply even if you specify IP address.
• For FH series/FZ5-1100 series, you can set WINS server.
• For FZ5-L series/FZ5-600 series, WINS server setting depends on your network environment.

Error Setting [Other]

Normally, when an error occurs, an error signal is output to the communication module in use and measurement
is stopped. Using this function, you can select whether to output an error signal or show a dialog when a
specified error occurs each of Lines.
1
On the main window, click [Tool] -[System setting] -[Other] -[Error Setting].
2
Valid error type selections and
current settings are displayed.
Note
For error messages and troubleshooting, refer to Error Messages and Troubleshooting (p.317).
3
Select [Error Type] to set the error operation on the error select window.
Vision System FH/FZ5 Series
User's Manual (Z365)
Setting the Operating Environment of the System
6
291