Setting item
• [Multi-input]
Mode
• Non-Multi-input
0 to 60s
Timeout
[10]
IMPORTANT
In the following cases, the system operates in Non-Multi-input mode, regardless of the settings for Mode.
• Camera Image Input HDR or Camera Image Input HDR Lite is used.
• Multiple Input image processing items are used in one Multi-trigger Imaging Task block.
• FZ-SQ camera is used with its light ON.
• Input image processing item is inserted outside of the range between Multi-trigger Imaging and Multi-trigger Imaging End
processing items.
There are restrictions below when FZ-FQ camera is used with its light ON.
• All Camera Image Input processing items operate with the settings for the Camera Image Input of the first Multi-trigger
Imaging Task in the flow.
• The system operates in Non-Multi-input mode. (It takes longer time to turn ON the READY signal).
• When the light of FZ-FQ camera is OFF, the camera operates in the same way as other camera does.
270
Multi-trigger Imaging Processing Function
Set value
[Factory default]
Set the processing mode of Multi-trigger Imaging Task
• Multi-input:
Select this if Multi-input mode is used in the Multi-trigger Imaging Task.
The Camera setting for the Input image processing item of the first Multi-
trigger Imaging Task is applied to that for other Input image processing
items that are executed in Multi-trigger Imaging Tasks.
• Non-Multi-input:
Cameras operate according to their own settings.
The Camera setting for the Input image processing item of the Multi-
trigger Imaging Task is applied to each execution of Input image
processing items. Because Camera setting is executed at each
execution of Input image preprocessing item, the time that READY
signal stays OFF becomes longer by several ms to several tens of ms
compared with that in Multi-input mode.
Set the time for timeout of Multi-trigger Imaging Task block.
It is a wait time between a Multi-trigger Imaging Task and the next one.
When a STEP signal is not input within the timeout time after the READY
signal turns ON, the Multi-trigger Imaging unit judgment will be NG.