Omron FH-1 series User Manual page 238

Vision sensor fh series; fz5 series
Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

3
Select the output method of STGOUT signal in the [STGOUT setting].
Please uncheck if you select [SHTOUT] in the [Output signal].
Parameter
Output without a
Camera connection
IMPORTANT
• The setting of [Output even if camera is not connected] can be used only with FH series. This can not be used with FZ5
series.
• The STGOUT signals that are applicable with the setting [Output even if camera is not connected] are as follows.
: FH-1000 and FH-3000 series: STGOUT 0 to 7
: FH-L series: STGOUT 0 to 3
• The setting for Multi-line Random-trigger Mode is as follows.
[Output signal setting]
: Configurable only in Output signal setting of Line 0. For other lines settings for Line 0 are commonly applied.
[Output even if camera is not connected]
: Selectable for each line.
• If a check is placed for [Output without a Camera connection] , set the pulse width for the [Camera Image Input FH]
processing item of corresponding STGOUT signal (STGOUT0 to STGOUT7)
Refer to Electronic Flash Setting in the Camera Image Input FH in the Vision System FH/FZ5 Series Processing Item
Function Reference Manual (Cat No. Z341).
• STGOUT0 to STGOUT7 is tied to the camera connector number of the sensor controller, not the camera number. When
you use CameraLink Medium Configuration or the Multi-line random-trigger mode, confirm the camera connector
number that corresponds to the camera number of Sensor Controller.
4
Set SHTOUT for each line in the [Line setting] area.
Parameter
SHTOUT signal delay [μs]
SHTOUT signal pulse width [μs]
SHTOUT signal pulse polarity
IMPORTANT
Do not perform next camera image input processing before SHTOUT signal output is completed. SHTOUT signal may not
be output.
Perform camera image input processing after confirming SHTOUT signal output completion, or set the SHTOUT signal
delay and SHTOUT signal pulse width so that the SHTOUT signal output is completed before camera image input
processing.
5
Click the [Close] Button.
236
Setting the Camera Conditions
Set value
[Factory default]
• Unchecked
Only STGOUT signal with which a Camera is connected is output.
• Checked
• [Unchecked]
STGOUT signals that are not connected with cameras will output,
• Checked
too. This setting can be used to change the brightness of the light
quickly. Use the [Electronic flash setting] in [Camera image input
FH] to configure the STGOUT signal.
Set value [Factory default]
[0] to 1,000
40 to 10,000 [5,000]
• [Positive]
• Negative
Description
Description
Sets the delay time from when exposure is
completed to when the SHTOUT signal turns ON
in increments of 10 μs.
Sets the time to output the SHTOUT signal in
increments of 10 μs.
Set the polarity of the SHTOUT signal.
Positive: The SHTOUT signal changes from OFF
to ON when the exposure ends.
Negative: The SHTOUT signal changes from ON
to OFF when the exposure ends.