Omron FH-1 series User Manual page 236

Vision sensor fh series; fz5 series
Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

2
Click a camera number to set the delay between STEP-cameras and then specify the delay
count value.
Item
Delay count
between STEP-
cameras
Transmission
speed
Note
• FH-1000 series/FH-3000 series:
Maximum number of settable camera is 8.
• FH -L series/FZ5 series/FZ5-L series:
Maximum number of settable is 4, camera 0 to camera 3.
• FH series Sensor Controller:
Connecting the camera by Medium Configuration, the image input time will be shorten.
Refer to Preparing the Controller and Cameras (p.76).
234
Setting the Camera Conditions
Set value
[Factory default]
• FH series Sensor Controller:
-4 to 511
[0]
(1 count is 30 μs)
• FZ5 series Sensor Controller:
0 to 511
[0]
(1 count is 30 μs)
[Standard] or High speed
Description
Sets the delay time from when the STEP signal is received to
when exposure begins for the selected Camera.
The delay time differs in FH series / FZ5 series.
• Delay time of FZ5 series Sensor Controller:
(=Delay count between STEP-camera × 30 μs + 122 μs
120 μs.
• Delay time of FH series Sensor Controller:
When using cameras other than FH-S@05R, the time
displayed for STEP-camera delay time is (STEP-camera
delay counts × 30 μs + 122 μs) + 120 μs.
When using the FH-S@05R camera, the time displayed for
STEP-camera delay time is (STEP-camera delay counts × 30
μs + 122 μs) + 470 μs.
When you connect a camera that supports High speed mode
using a camera cable shorter than 5m, image input time can be
shortened by selecting [High speed] for frame rate.
For details about frame rate values, refer to the Instruction
manual for the Camera.
The following cameras support [High speed]:
• FH-SC02/FH-SM02
• FH-SC04/FH-SM04
• FH-SC12/FH-SM12
*1
) +
Vision System FH/FZ5 Series
User's Manual (Z365)

Advertisement

Table of Contents
loading

Table of Contents