Precautions for Correct Use

Installation and Storage Sites for FH-1000 series/FH-3000 series/FZ5-1100 series/
FZ5-600 series/FZ5-L series
Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to +50°C
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 35 to 85%
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals
Installation and Storage Sites for FH-L series
Install and store the product in a location that meets the following conditions:
• Surrounding temperature of 0 to +55°C (-25 to +70°C in storage)
• No rapid changes in temperature (place where dew does not form)
• Relative humidity of between 10 to 90%
• No presence of corrosive or flammable gases
• Place free of dust, salts and iron particles
• Place free of vibration and shock
• Place out of direct sunlight
• Place where it will not come into contact with water, oils or chemicals
• Place not affected by strong electro-magnetic waves
• Place not near to high-voltage, or high-power equipment
Orientation of Product
• For good heat dissipation, install the product only in the position written this manual or Instruction sheet so
as not to block the ventilation holes.
Ambient Temperature
• For good heat dissipation, keep the distance written this manual or Instruction sheet.
• Do not install the product immediately above significant heat sources, such as heaters, transformers, or
large-capacity resistors.
• Do not let the ambient temperature exceed an operating temperature range.
• Provide a forced-air fan cooling or air conditioning if the ambient temperature is near the upper range of
operating temperature range so that the ambient temperature never exceeds the upper range of operating
temperature range.
Noise Resistance
• Do not install the product in a cabinet containing high-voltage equipment.
• Do not install the Sensor Controller within 200 mm of power cables.