IMPORTANT
• The data saved in the Controller memory or RAM disk is deleted when the Controller is restarted.
• If external storage is specified as the save destination, the processing time may be longer or may fluctuate. Be sure to
check functionality thoroughly before starting operation.
• If images and data are logged to a network drive, the use of the multi-input function and other heavy measurement loads
on the Controller may slow down communications and cause logging errors. In this case, set the measurement takt time
so that there is some leeway.
Note
Image Logging
• When the number of files in the save destination folder increases, the time needed to save images increases.
• If you specify Disable in [Camera Image Input], its camera image will not be saved.
Number of Images That Can Be Saved
• This will depend on the size and resolution of the images and the number of Cameras connected.
• The number of images that can be saved on the RAM disk in the Controller or a external storage depends on available
space.
•If the RAM disk is selected, the memory available in the RAM disk
•If external storage is selected, it depends on the external storage capacity.
• When you use the external memory device, some limitations may be required due to the combination of file format and
Sensor Controller model.
Sensor Controller
Model
FZ5-L series
• When you save the Image fileto the
FZ5-600 seires
immediately below root file, the
number of the Image files can be
saved is around 126.
• When you save the Image file to one
folder, the number of the Image files
can be saved is 999.
• When you save the Image file to the
FH series
FZ5-1100 series
immediately below root file, the
number of the Image files can be
saved is around 126.
• When you save the Image file to one
folder, the number of the Image files
can be saved is 16000.
*1:
This limitation will be initialized at the restarting of the Sensor Controller.
Loading Data to a Computer
• Default settings are set so that logging data is saved in the RAM disk in the Controller.
When logging data is loaded to a computer, set [external storage] as the save destination.
Logging data is first saved to the RAM disk in the Controller.
It can then be copied from the RAM disk and saved to the [external storage] using [Copy files] in [Save to file].
Vision System FH/FZ5 Series
User's Manual (Z365)
File Format
FAT16
• When you save the Image file
to one folder, the number of
image files can be saved is
999.
• The maximum number of
folders which can be created
*1
is 999.
The total number of the Image
file can be saved to the
immediately below root file or to
one folder is around 16000.
FAT32
1NTFS is not supported
in FZ5-L/FZ5-600 series
Sensor Controller.
*1
No limitation of file
format.