Omron FH-1 series User Manual page 130

Vision sensor fh series; fz5 series
Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

9
Set the image logging priority conditions.
When the measurement takt time is short, a
time lag may occur in writing from the
Controller memory (RAM) to the RAM disk in
the Controller and a temporary lack of
available space in the Controller memory may
occur. Select whether logging or
measurement has priority at these times.
Parameter
Logging priority
Note
To save all images that are logged, set the operation mode of the Sensor Controller to [Standard] (Operation Mode) and the
Logging setting (logging condition) to [Logging]. At the same time, select [Tool] − [System Settings] − [Startup], and turn
OFF [Parallel execute] under the operation mode In the startup settings.
10
Click [Data Logging].
The data format is set with the Data Logging
processing item.
Parameter
Data logging
11
Set the logged data save destination.
Parameter
Folder name
12
Click [Apply].
128
Useful Functions for Operation
Set value [Factory default]
[Logging]
Measurement
Set value [Factory default]
[None]
Only NG
All
Set value [Factory default]
• [RAM Disk]
• USBDisk
Description
Image logging is prioritized over the following measurement.
If overwriting of measurement images as logging images in the
Controller memory (RAM) is not available, measurement is
continued until it becomes available. When overwriting becomes
available, the next measurement trigger can be accepted.
Starting measurement is prioritized over image logging.
If overwriting of measurement images as logging images in the
Controller memory (RAM) is not available, the measurement
image is discarded, and the next measurement trigger is
accepted.
Description
Measurement data is not saved.
Measurement data is saved when an NG error occurs in a unit
before a [Data Logging] unit. If an NG error occurs after the [Data
Logging] processing unit, data logging is not performed.
All measurement data is saved.
Description
The data is saved in the specified destination folder (RAM disk or
USB disk). Set the file name with the [Data Logging] processing
unit. (Maximum number of characters: 128 single-byte characters)
Vision System FH/FZ5 Series
User's Manual (Z365)