Encoder Trigger Setting [Other] - Omron FH-1 series User Manual

Vision sensor fh series; fz5 series
Hide thumbs Also See for FH-1 series:
Table of Contents

Advertisement

Encoder trigger setting [Other]

1
In the Main Window, select [System
setting] − [Other] − [Encoder trigger
setting] from the [Tool] menu.
2
Set the target encoder.
Parameter
Use encoder trigger
Encoder input type
Resolution [pulse/
rotation]
Count rotations with
pulse Z
3
Set the advanced settings for the trigger
as necessary.
Vision System FH/FZ5 Series
User's Manual (Z365)
Set value
[Factory default]
• Selected
Set whether to use an encoder trigger.
• [Not selected]
• [Open collector]
Select the output format of the encoder to be connected.
• Line driver
Set how many pulses equal one rotation. Set this parameter according to
[1] to 65535
the resolution of the encoder.
When this check box is selected, pulse Z is used to determine whether a
• Selected
full rotation is made. When this check box is cleared, a full rotation is
• [Not selected]
determined by whether the number of pulses on phase A has reached the
resolution of phase A.
Description
Setting the Operating Environment of the System