Memory Usage Guidance For Processing Items

Free space is required in the application memory or data memory (FH-L series/FZ5-600 series Sensor Controller only) in
order to add a processing unit to the measurement flow. The amount of free space required in memory consists of both the
amount necessary to add a processing unit to the measurement flow, and the amount necessary to configure settings for the
added unit and execute measurement.
When adding a new processing unit to the measurement flow, or if the memory becomes insufficient when settings are
configured, refer to the table below for the approximate amount of memory used and delete a processing unit from the
measurement flow or adjust the processing unit settings.
The amount of used memory and free data memory can be checked from the menu of Memory Consumption Monitor on the
Measurement Management Bar or the system menu.
Reference: Checking the Memory Consumption and Percentage of Memory Used (p.136) and Checking System
Information [System Information] (p.293).
To adjust each processing unit, refer to the section for each processing item in the Processing Item Function Reference
Manual. (Reference: Processing Item Function Reference Manual (Cat. No. Z341))
Item
Search
Flexible Search
Sensitive Search
ECM Search
EC Circle Search
Shape Search II
Shape Search III
Ec Corner
Ec Cross
Classification
Edge Position
Edge Pitch
Scan Edge Position Approx. 2KB
Scan Edge Width
360

Memory Usage Guidance For Processing Items

Approximate memory usage
Adding to
Change due to settings
measurement flow
Approx. 544 MB (for monochrome image)
Approx. 2KB
Approx. 1609 MB (for color image)
Approx. 2,655MB (for monochrome image)
Approx. 2KB
Approx. 7,856MB (for color image)
Approx. 1,088MB (for monochrome image)
Approx. 8KB
Approx. 3,218MB (for color image)
Approx. 2KB
Approx. 2MB
Approx. 24KB
Approx. 1MB
Approx. 6KB
Approx. 57MB
Approx. 3KB
Approx. 335MB
Approx. 62KB
No change
Approx. 34KB
No change
Approx. 543,477MB
(for monochrome image)
Approx. 41KB
Approx. 1,608,757MB
(for color image)
Approx. 1KB
Approx. 1MB
Approx. 5 KB
Approx. 1MB
Approx. 12MB
Approx. 2KB
Approx. 23MB
Main settings that affect change of
memory used
Model registration figure, model parameters,
saved settings of model registration image,
image size, number of detections, whether
image is color or monochrome.
Model registration count, model registration
figure, model parameters, image size,
whether image is color or monochrome.
Model registration figure, model parameters,
image size, whether image is color or
monochrome.
Model registration figure, error model
registration figure, extraction amount of edge
extraction, image size.
-
Model registration figure, model parameters,
saved settings of model registration image,
image size, shape of edge in image.
Model registration figure, model parameters,
saved settings of model registration image,
image size, number of detections, shape of
edge in image.
-
-
Model registration count, model registration
figure, model parameters, image size,
whether image is color or monochrome.
Measurement region figure, image size.
Measurement region figure, image size.
Measurement region figure, number of
measurement points, image size.
Measurement region figure, number of
measurement points, image size.
Vision System FH/FZ5 Series