• To use EtherNet/IP, use an EDS file that
matches the line to be used.
• Specify different I/O memory addresses
for the sending area and receiving area
for line 0 and for lines 1 to 7.
The value of the STEP signal filter for the
most recently set line is applied to all lines.
• The Communications Module is set for
each line.
• The communications settings can be set
only for line 0.
The settings are applied as shown below.
[Output control]: The same setting is used for
all lines.
[Output period]: The same setting is used for
all lines.
[Output setting]: This is set for each line.
• The I/O ports (areas) for communications
between the FH series Sensor Controller
and master are assigned as shown below.
I/O ports for the Command Area: I/O
ports are assigned for each line.
I/O ports for the Response Area: I/O ports
are assigned for each line.
I/O ports for the Output Area: I/O ports
are assigned for each line.
The I/O ports in the Sysmac Error Status
Area are shared by all lines.
• The maximum data size that can be
output depends on the number of lines,
as shown in the following table.
1 to 5 lines: 256 bytes max.
6 to 8 lines: 128 bytes max.
FZ5 series:
FZ5-1100 series
• To use EtherNet/IP, use an EDS file that
matches the line to be used.
• Specify different I/O memory addresses for
the sending area and receiving area for line
0 and for line 1.
The value of the STEP signal filter for each line
is applied to each line.
---