Selection Guide for Operation mode

A guide to using the most suitable operation mode for your purpose.
Measures on multiple lines
: Trigger input for each line.
: Trigger input for each line.
Multi-line Random-trigger
mode
• This mode can input the
trigger to each lines.
• Input or Output of
communication can be
limited depending on used
the number of lines.
• Processing time may be
longer than Standard mode
if you increase the number
of lines.
*1:
This mode name is changed from Ver. 5.50. This function name is Single-line High speed mode in old model.
*2:
This mode name is changed from Ver. 5.50. This function name is High-speed Logging mode in old model.
Reference:
Multi-input Function (p.241)
Reference:
Functional Comparison between the FH-series and FZ5-series Controllers (p.45)
Vision System FH/FZ5 Series
User's Manual (Z365)
Select Operation mode
You want to measure
on multiple lines.
Adjust without stopping
machines
: Can change the settings with
measuring.
: A part of the processing
items can be limited.
Non-stop Adjustment mode
• This mode allows changes
to be made to settings while
running measurement
processing.
• Some processing items
may not be applied to use
or may be restricted.
• Using commands from the
external device are
restricted.
• Unintended operation may
be occurred if you change
the Scene while this
function is running.
You want to make
adjustments without
stopping
measurement.
Executes the measurement as
many as possible by unit time.
: Executes the measurement alternately
using 2 cores. 2 core for fastest
measurement speed.
: For this measurement, need to use the
Multi-input function.
: A part of the processing items can be
limited.
Double Speed Multi-input
*1
mode
• For this Operation mode,
need to use the Multi-input
function.
• In this mode, processing
time of all Operation mode
in a unit time may be
longest.
• In this function, some
processing unit items are
not applied or limited.
• Using the command from
external device is limited.
You want to shorten the
single measurement time.
For fastest
measurement
processing time.
: No limit all functions.
*2
Standard mode
• In this mode, one
measurement time will be
fastest in all of the
Operation mode.
• All functions can be used
without restriction.
Setting the Operation Mode
6
239