Decoding Data To Seven-Segment Display Data - Mitsubishi Electric MELSEC iQ-R Series Programming Manual

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Decoding data to seven-segment display data

SEG(P)
RnPCPU
RnPCPU
RnCPU RnENCPU
(Process)
(Redundant)
These instructions decode the data consisting of 0 to F specified by the lower 4 bits of the device to seven-segment display
data.
Ladder
(s)
(d)
FBD/LD
EN
ENO
s
d
■Execution condition
Instruction
SEG
SEGP
Setting data
■Description, range, data type
Operand
Description
(s)
Decode data or the device where the decode data is stored
(d)
Device for storing the decoded data
EN
Execution condition
ENO
Execution result
■Applicable devices
Operand
Bit
X, Y, M, L,
J\
SM, F, B, SB,
FX, FY
(s)
(d)
RnSFCPU RnSFCPU
(Standard)
(Safety)
Execution condition
Word
T, ST, C, D, W,
U\G, J\,
SD, SW, FD, R,
U3E\(H)G
ZR, RD
ST
ENO:=SEG(EN,s,d);
ENO:=SEGP(EN,s,d);
Range
Data type
-32768 to 32767
16-bit signed binary
16-bit signed binary
Bit
Bit
Double word Indirect
Z
LT, LST,
LZ
LC
6.6 Data Conversion Instructions
Data type (label)
ANY16
ANY16
BOOL
BOOL
Constant
Others
specification
K, H E
$
6 BASIC INSTRUCTIONS
6
475

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents