Show Rmon Alarm - D-Link DGS-510 Reference Manual

Gigabit ethernet smartpro switch
Table of Contents

Advertisement

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
Command Default Level
Level: 12.
Usage Guideline
If the log and not the trap is specified, the created entry will cause a log entry to be generated on an
event occurrence. If the trap and not the log is specified, the created entry will cause an SNMP
notification to be generated on an event occurrence.
If both the log and trap options are specified, the created entry will cause both the log entry and the
SNMP notification to be generated on event occurrence.
Example
This example shows how to configure an event with an index of 13 to generate a log on the
occurrence of the event.
Switch# configure terminal
Switch(config)# rmon event 13 log owner it@domain.com description ifInNUcastPkts is
too much
Switch(config)#
57-5

show rmon alarm

This command is used to displays the alarm configuration.
show rmon alarm
Parameters
None.
Default
None.
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
This command displays the RMON alarm table.
Example
This example shows how to displays the RMON alarm table.
Switch# show rmon alarm
Alarm index 23, owned by IT
Monitors OID: 1.3.6.1.2.1.2.2.1.10.1
every 120 second(s)
Taking delta samples, last value was 2500
Rising threshold is 2000, assigned to event 12
Falling threshold is 1100, assigned to event 12
On startup enable rising or falling alarm
Switch#