show rmon alarm
The show rmon alarm User or Privileged EXEC mode command displays alarm configuration.
Syntax
show rmon alarm number
Parameters
•
number — Specifies the alarm index. (Range: 1 - 65535)
Default Configuration
This command has no default configuration.
Command Mode
User or Privileged EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays RMON 1 alarms.
Console> show rmon alarm 1
Alarm 1
-------
OID: 1.3.6.1.2.1.2.2.1.10.1
Last sample Value: 878128
Interval: 30
Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Desc rip t io n
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample Value
The statistic value during the last sampling period. For example, if the sample type is
delta, this value is the difference between the samples at the beginning and end of the
period. If the sample type is absolute, this value is the sampled value at the end of the
period.
Page 208
RMON Commands