Yamaha RIVAGE PM10 Operation Manual page 369

Digital mixing system
Hide thumbs Also See for RIVAGE PM10:
Table of Contents

Advertisement

Messages
Messages
Message
[xx] connected
Device xx is connected.
[xx] disconnected!
Device xx is disconnected.
A Bay Link was released.
BAY LINK released.
This message appears if a bay link is released due to changes in
the SEL LINK settings.
Bay x does not exist.
You attempted to operate a non-existing bay (only for CS-R10-S).
The maximum number of events (2000) allowed on the list has
Cannot add event! (event list full)
been reached. You cannot add more events.
Cannot bookmark this popup
This popup window cannot be bookmarked.
Cannot close this page
This page cannot be closed.
You cannot change the Overlay offset to a value outside the
Cannot edit overlay!
specified range.
Cannot edit scene! (extracting scene data)
Cannot load file (extracting scene data)
Cannot recall! (extracting scene data)
Cannot save file (extracting scene data)
One of these messages will be displayed if you attempt to
perform an invalid operation during extraction of scene data, or if
Cannot shutdown (extracting scene data)
you try to use the Global Paste function only on the standalone
control surface or only in PM10 Editor.
Cannot store! (extracting scene data)
Cannot undo! (extracting scene data)
Cannot update! (extracting scene data)
Cannot mount!
Cannot load partial data now! (data in
Partial data cannot be loaded.
console corrupt; only ALL file can be
Data inconsistency has occurred inside the console. Load entire
loaded)
data all at once.
Cannot mount the plug-in. No DSP
Additional plug-ins cannot be mounted due to insufficient DSP
resources available.
resources.
Cannot mount! (plug-in too large for
Plug-in failed to mount due to insufficient size of the slot.
selected location)
Cannot open the bookmarked page
The bookmarked page failed to open.
Cannot paste!
The character string in the copy buffer is too long to be pasted.
Cannot perform this action! (scene data is
One of these messages will be displayed if you attempt to
now being extracted)
perform an invalid operation during extraction of scene data or
Cannot perform this action! (global paste
during the Global Paste operation.
in progress)
Cannot recall! (Internal error)
The scene cannot be recalled due to an internal error.
Meaning
369
Message
Control surface data is corrupt and cannot be saved.
To recover the data, access the DEVICE SYNC screen, and then re-
sync data in the DSP → CS sync direction. Alternatively, access the
Cannot save now! (mixing data corrupt)
SAVE/LOAD screen and load the control surface setting file.
Otherwise, initialize the control surface
Cannot Select for GLOBAL PASTE! (too
You cannot select more than 100 scenes for the Global Paste
many scenes; max. 100)
operation.
Cannot store! (too many scenes; max.
The scene cannot be stored because the maximum number
1000)
(1,000) of scenes that can be stored has already been reached.
If the control surface or PM10 Editor is connected with the DSP
Cannot sync in this direction! (DSP is
engine online, you will be unable to sync to transfer data to the
already online)
DSP engine.
Data is corrupt. Syncing in this direction is not available.
If the control surface data is corrupt, syncing in the CS → DSP
Cannot sync in this direction! (mixing data
direction is not available
corrupt)
If the DSP engine data is corrupt, syncing in the DSP → CS
direction is not available
Cannot trigger event! (event not found)
You cannot trigger any events from a device other than the
Cannot trigger event! (Event List can only
console, or non-existing events.
be operated from main console)
Cannot trigger event! (event list disabled)
If an event list is disabled, you cannot recall events.
Cannot undo! (Internal error)
The Undo operation failed due to an internal error.
Cannot update scene!
The scene failed to be stored due to an internal error.
Channel pair made
The channels are paired.
Channel pair made. (plug-ins and GEQ's
The channels are paired. Inserted plug-ins and GEQ are now
have been unmounted)
unmounted.
Channel pair released
The channel pair was canceled.
Channel pair released. (plug-ins and GEQ's
The channel pair was canceled. Inserted plug-ins and GEQ are
have been unmounted)
now unmounted.
Channel set to default
Channel data is reset to its default value.
Console initialization [XX] completed
The console initialization is complete.
The system detected conflict in the firmware version of the
Console local I/O firmware version
console's built-in Local I/O section. Update the firmware for the
conflict! Try updating console firmware.
entire console, and then make sure that there will be no conflict.
An internal error occurred on the console. Connections inside the
Console local I/O model type conflict!
operating panel may be faulty. Please contact your Yamaha
dealer.
The system cannot communicate with the console's built-in Local
Console local I/O not responding!
I/O section. Refer to the PM10 Firmware Update Guide (separate
Try updating console firmware.
document) to use PM10 FIRMWARE UPDATER for a recovery
operation.
CONTENTS
FUNCTION MAP
Meaning
RIVAGE PM10 Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents