Maintenance  Adjusting the detection point of the touch screen panels
Adjusting the detection point of the
touch screen panels
Follow the steps below to correctly align the positions of the LCD display and the touch screen
panels.
1.
Press the SETUP button on the menu bar to access the SETUP screen.
2.
Press the MAINTENANCE button to access the MAINTENANCE popup window.
This window includes several pages, which you can switch between using the tabs located at
the top of the window.
3.
Press the TOUCH CALIB tab.
The TOUCH SCREEN CALIBRATION screen will appear, enabling you to calibrate the touch
screen panels.
4.
Press the LEFT PANEL button to calibrate the left touch screen panel. Press the
RIGHT PANEL button to calibrate the right touch screen panel.
You can also select and calibrate both left and right panels simultaneously.
5.
Press the START button.
A cross-shaped cursor will appear in the screen a total of four times. Press each location at
which it appears.
NOTE
To set the detection points accurately, press the cross-shaped cursor from the position and
posture in which you normally operate the unit.
6.
Press the FINISH button.
The calibration values will be saved in internal memory.
351