MIDI/GPI  Using GPI OUT
Using GPI OUT
The GPI OUT ports of the GPI OUT connector enable you to control an external device by
performing operations on the RIVAGE PM10 system.
1.
Connect an external device to the GPI connector on the control surface.
2.
Press the SETUP button on the menu bar to access the SETUP screen.
3.
Press the MIDI/GPI button to open the MIDI/GPI popup window.
This window includes several pages, which you can switch between using the tabs located at
the top of the window.
4.
Press the GPI tab to access the GPI page.
1
GPI OUT status indicator
Indicates the status of the voltage that is being output from each GPI OUT port.
2
POLARITY MODE select button
Enables you to select the polarity of the GPI OUT port.
3
4
2
1
345
................(Low active) Grounded when the GPI OUT port is active.
................(High active) Open when the GPI OUT port is active.
3
GPI OUT SETUP popup button
Press this button to access the GPI OUT SETUP popup window.
The button shows the name of the currently-selected function or parameter.
4
TEST button
While this button is on, the corresponding GPI OUT port will become active and output a
control signal.
5.
Specify the POLARITY MODE based on the specifications of the external device
you are using.
6.
To assign the function or parameter that you want to control, press the GPI OUT
SETUP popup button.