Channel Job  About DCAs
Using DCAs
Use the Channel Strip section to control the DCAs.
• Level adjustment: fader ......................... You can adjust the level of the channels assigned to
• Toggling between on and mute:
[ON] key.................................................... When you press an [ON] key in the Channel Strip
• Cue monitoring: [CUE] key .................. When you press a [CUE] key in the Channel Strip
that DCA while preserving the relative level
differences among the channels. The channel fader
operation will not be linked at this time.
section to make the key indicator go dark, the [ON]
key for each channel assigned to that DCA will
flash, and these channels will be muted (the same
state as when the faders are lowered to the –∞dB
position).
NOTE
While DCA is muted, these DCA channels will not be
muted if the send point for MIX/MATRIX SENDS is
set to PRE. If it is set to POST, these channels will be
muted.
section to make the key indicator light, the [CUE]
keys for the channels assigned to that DCA will
blink, and cue monitoring will be enabled. For more
information about cue, refer to
"Using the Cue
function"
(page
144).
DCA Roll-out function
All channels assigned to a DCA can be temporarily recalled (rolled out) to other bays and controlled
individually.
You can use the PREFERENCES setting to change how the channels will be rolled out
■ DCA ROLL-OUT operation
1.
Press the [DCA] key on the top panel to select the DCA layer.
2.
Press the [SEL] key for the DCA you want to roll out.
The corresponding channels will be rolled out on the panel according to the DCA ROLL-OUT
setting in PREFERENCES.
3.
To exit from ROLL-OUT mode, select a different bank, press the [HOME] key, or
press the [SEL] key again for the same DCA.
NOTE
• You cannot turn Roll-out mode on while operating a DCA (for example, while assigning
channels or editing the group name).
• If the number of channels assigned to a DCA exceeds the number of faders in the block (that
is a roll-out target), you will be unable to control extra channels.
• If the number of channels assigned to a DCA exceeds the number of faders on a particular
bay for roll-out, you will be able to scroll extra channels to the left or right inside the block using
the channel strip encoder or screen encoder (only on bay L or C). While you are turning the
knob, a message "DCA ROLLOUT: DCA members scrolling" will appear on the bottom of the
touch screen or external monitor screen.
Rolling-out channels using the DCA Roll-out function
You can use the PREFERENCES setting to change how the channels will rolled out
The SEL LINK and No. OF BAYS TO USE settings will determine which bay will be used for the
roll-out.
• If you use the DCA ROLL-OUT function on a bay that is not linked in the SEL LINK section,
channels will be rolled out only on that bay.
• If you use the DCA ROLL-OUT function on a bay that is linked to another bay in the SEL LINK
section, channels will be rolled out on that bay and its linked bay. The No. OF BAYS TO USE
parameter in the PREFERENCES settings will determine the number of bays on which to roll
out the channels.
NOTE
You cannot use the DCA ROLL-OUT function on multiple bays simultaneously. If you try to do so, the
message "Only one DCA can be rolled out at one time" will appear near the bottom of the touch screen