Table 11-2
SUBSYSTEM COMMANDS
CALCulate[1|2]
:MARKer[1|2|8]:X <num>
CALCulate[1|2]
:MARKer[1|2|8]:X:ABS <num>
CALCulate[1|2]
:MARKer[1|2|8]:Y?
CALCulate[1|2]
:MARKer[1|2|8]:Y:INDuctance?
CALCulate[1|2]
:MARKer[1|2|8]:Y:MAGNitude?
CALCulate[1|2]
:MARKer[1|2|8]:Y:PHASe?
CALCulate[1|2]
:MARKer[1|2|8]:Y:REACtance?
CALCulate[1|2]
:MARKer[1|2|8]:Y:RESistance?
CALCulate[1|2]
:MATH[:EXPRession] <expr>
1. <expr> and EXPR represent expressions, a parameter type that consists of mathe-
matical expressions that use character parameters and are enclosed in parentheses.
CALCulate (7 of 7)
1
Programmer's Guide
FORM
NR3
Sets the specified marker frequency
(or power if in power sweep).
NR?
Sets a marker to an absolute value
(such as frequency or amplitude). The
set value is not relative to a reference
marker if one is enabled.
query
Queries the specified marker
only NR3
amplitude.
query
Queries the specified marker's
only NR3
inductance when in Smith chart
format.
query
Queries the specified marker's
only NR3
magnitude when in polar format.
query
Queries the specified marker's phase
only NR3
value when in polar format.
query
Queries the specified marker's
only NR3
reactance value when in Smith chart
format.
query
Queries the specified marker's
only NR3
resistance value when in Smith chart
format.
EXPR
Selects a trace math expression —
choose measurement trace from
(IMPL) for "data only" or
(IMPL/CH<1|2>SMEM) for "data /
memory".
SCPI Command Summary
SCPI Device Command Summary
DESCRIPTION
11-11