Leica GPS1200+ Technical Reference Manual page 324

Geodetic satellite receiver
Hide thumbs Also See for GPS1200+:
Table of Contents

Advertisement

Manage...\Configuration Sets
Step
Description
DMASK (F3) configures the selected display mask.
7.
CONT (F1)
8.
CONFIGURE Coding & Linework
<Quick Code: Off>
<Attributes: Default Values>
9.
CONT (F1)
10.
CONFIGURE Logging of Raw Obs
<Log Raw Obs: Static Only>
For static operations with long baselines and over long time: <Log
Rate: 15.0s> or <Log Rate: 30.0s>
For reference stations for post-processed ensure that <Log
Rate:> is the same rate as at the rover.
11.
FILES (F6)
12.
CONFIGURE Raw Observation Files
<Use Separate Files: No>
13.
CONT (F1) leads back to CONFIGURE Logging of Raw Obs
14.
CONT (F1)
15.
CONFIGURE Point Occupation Settings
<Pt Occupation: Normal>
<Auto OCCUPY: No>
GPS1200+
Refer to
chapter
19.3
19.5
19.5
19.6