Subaru IMPREZA 2002 Service Manual page 316

Hide thumbs Also See for IMPREZA 2002:
Table of Contents

Advertisement

STARTER
STARTINGKHARGING SYSTEMS
2) Load test:
Apply the specified braking torque to starter. The
condition is satisfactory if the current draw and
starter speed are within specifications.
Load test (Standard):
Voltage /Load
Non-Turbo MT vehicles
Turbo MT vehicles
AT vehicles
Current / Speed
7.5 W8.6 N.m (0.88 kgf-m, 6.3 ft-lb)
8 V9.3 N.m (0.95 kgf-m, 6.9 ft-lb)
7.7 W6.0 N-m (1.63 kg-m, 11.8 ft-lb)
Non-Turbo MT vehicles
Turbo MT vehicles
AT vehicles
300 N920 rpm or more
280 N860 rpm or more
400 An40 rpm or more
3) Lock test:
With the starter stalled, or not rotating, measure the
torque developed and current draw when the volt-
age is adjusted to the specified voltage.
Lock test (Standard):
Voltage / Current
Non-Turbo MT vehicles
4 V/650 A or less
Turbo MT vehicles
5 V/515 A or less
AT vehicles
3.5 V/940 A or less
Non-Turbo MT vehicles
Turbo MT vehicles
AT vehicles
Torque
14.7 N-m (1.50 kgf-m, 10.8 ft-lb) or more
16 N-m (1.63 kgf-m, 11.8 ft-lb) or more
28.9 N-m (2.95 kgf-m, 21.3 ft-lb) or more
sc-12